28,674 research outputs found

    Comparison of pilot effective time delay for cockpit controllers used on space shuttle and conventional aircraft

    Get PDF
    A study was conducted at the Dryden Flight Research Facility of NASA Ames Research Center (Ames-Dryden) to compare pilot effective time delay for the space shuttle rotational hand controller with that for conventional stick controllers. The space shuttle controller has three degrees of freedom and nonlinear gearing. The conventional stick has two degrees of freedom and linear gearing. Two spring constants were used, allowing the conventional stick to be evaluated in both a light and a heavy configuration. Pilot effective time delay was obtained separately for pitch and roll through first-order, closed-loop, compensatory tracking tasks. The tasks were implemented through the space shuttle cockpit simulator and a critical task tester device. A total of 900 data runs were made using four test pilots and one nonpilot (engineer) for two system delays in pitch and roll modes. Results showed that the heavier conventional control stick had the lowest pilot effective time delays. The light conventional control stick had pilot effective time delays similar to those of the shuttle controller. All configurations showed an increase in pilot effective time delay with an increase in total system delay

    Fractals and Scars on a Compact Octagon

    Get PDF
    A finite universe naturally supports chaotic classical motion. An ordered fractal emerges from the chaotic dynamics which we characterize in full for a compact 2-dimensional octagon. In the classical to quantum transition, the underlying fractal can persist in the form of scars, ridges of enhanced amplitude in the semiclassical wave function. Although the scarring is weak on the octagon, we suggest possible subtle implications of fractals and scars in a finite universe.Comment: 6 pages, 3 figs, LaTeX fil

    Measurements of Pilot Time Delay as Influenced by Controller Characteristics and Vehicles Time Delays

    Get PDF
    A study to measure and compare pilot time delay when using a space shuttle rotational hand controller and a more conventional control stick was conducted at NASA Ames Research Center's Dryden Flight Research Facility. The space shuttle controller has a palm pivot in the pitch axis. The more conventional controller used was a general-purpose engineering simulator stick that has a pivot length between that of a typical aircraft center stick and a sidestick. Measurements of the pilot's effective time delay were obtained through a first-order, closed-loop, compensatory tracking task in pitch. The tasks were implemented through a space shuttle cockpit simulator and a critical task tester device. The study consisted of 450 data runs with four test pilots and one nonpilot, and used three control stick configurations and two system delays. Results showed that the heavier conventional stick had the lowest pilot effective time delays associated with it, whereas the shuttle and light conventional sticks each had similar higher pilot time delay characteristics. It was also determined that each control stick showed an increase in pilot time delay when the total system delay was increased

    Equivalence between two-mode spin squeezed states and pure entangled states with equal spin

    Full text link
    We prove that a pure entangled state of two subsystems with equal spin is equivalent to a two-mode spin-squeezed state under local operations except for a set of bipartite states with measure zero, and we provide a counterexample to the generalization of this result to two subsystems of unequal spin.Comment: 6 pages, no figure

    Piggyville; The Guard Reports of Seeing the Light

    Get PDF
    Mississippi Poets: A Showcas

    Rapid rotation of micron and submicron dielectric particles measured using optical tweezers

    No full text
    We demonstrate the use of a laser trap (‘optical tweezers’) and back-focal-plane position detector to measure rapid rotation in aqueous solution of single particles with sizes in the vicinity of 1 μm. Two types of rotation were measured: electrorotation of polystyrene microspheres and rotation of the flagellar motor of the bacterium Vibrio alginolyticus. In both cases, speeds in excess of 1000 Hz (rev s−1) were measured. Polystyrene beads of diameter about 1 μm labelled with smaller beads were held at the centre of a microelectrode array by the optical tweezers. Electrorotation of the labelled beads was induced by applying a rotating electric field to the solution using microelectrodes. Electrorotation spectra were obtained by varying the frequency of the applied field and analysed to obtain the surface conductance of the beads. Single cells of V. alginolyticus were trapped and rotation of the polar sodium-driven flagellar motor was measured. Cells rotated more rapidly in media containing higher concentrations of Na+, and photodamage caused by the trap was considerably less when the suspending medium did not contain oxygen. The technique allows single-speed measurements to be made in less than a second and separate particles can be measured at a rate of several per minute
    • …
    corecore